For hazardous applications, such as nuclear fuel pools, industrial refineries and gas plants, we provide highly specialized etched disc self-cleaning filtration systems. Etched Disc Propellant Filter VACCO etched disc propellant filters are installed in the Propulsion Propellant System aboard the cruise and descent stages of the MSL mission.
عرض المزيدSofi Filter in process plant. ... The Sofi Filter is designed for industrial processes in which closed water circulation is used or waste contamination needs to be minimised. The filtration is done with over-pressure, in other words the bubble-point of the membrane is exceeded. ... Process flow for the Sofi Filter. Case study 3 – Treating ...
عرض المزيدTwo disc filters were retrofitted in half the space occupied by the travelling filters, to increase plant capacity at a facility in New Zealand. Disc filters at a facility in Qatar. Disc filters allowed capacity expansion in the existing concrete chlorine basin footprint at Wuxi, China A disc filter installation in Pennsylvania.
عرض المزيدDesalitech's ReFlex products are highly efficient and adaptable reverse osmosis systems backed by Desalitech's maximum recovery guarantee. Desalitech's ReFlex products work by recirculating pressurized …
عرض المزيدHydraulic circuit that is predominantly used in mobile hydraulics. Here the directional valves are closed in the centre position; the flow rate is either routed. Via an idle circulation valve (on constant pumps) or; On variable pumps with power limiting and pressure limitation set to minimum flow at pressure or
عرض المزيدnent (absorber), which absorbs exhaled carbon dioxide and it is not necessary to give high fresh gas flows as in Mapleson systems. When the adjustable pressure limiting (APL) valve is closed and all the exhaled gases without carbon dioxide are returned to the patient, the system becomes a totally closed one. Such a circle system can be used with flows as …
عرض المزيد(Finland) in a closed circuit with a screen reaching 80% passing 41 mm. Fine crushing is carried out in a grinding roller in a closed circuit with screens and then grinding is carried out in a ball mill in a closed circuit with hydrocyclones up to 80% passing 250 μm [3]. The semiautogenous grinding process is very sus-
عرض المزيدDisc filters are high rate inside-out filtration systems that remove solids from the influent stream. Evoqua offers a suite of disc filters with modular design, small footprint, and …
عرض المزيدThe plant treats a blend of 25% trickling filter and 75% activated sludge effluent from OC San by full advanced treatment consisting of microfiltration (MF), RO, …
عرض المزيد4. Gold-loaded carbon desorption and electrowinning stage The desorption electrowinning of gold-loaded carbon mainly adopts the process of heating and pressurizing desorption, high temperature, and constant pressure combined with a closed-circuit circulation process. There are more mature desorption electrowinning devices with a higher degree ...
عرض المزيدLenntech is introducing the innovative Closed Circuit Reverse Osmosis (CCRO) technology to the water and process industry in Europe. CCRO is revolutionizing the purification and recovery of water across a variety of industries. While traditional RO systems create excess brine waste, do not use water supplies efficiently and consume …
عرض المزيدThe filter disc can have a number of weaving types especially if it is a wire mesh. The weaving types of the wire mesh include twill weave, plain weave and Dutch weave among others. Also, the weaving type will affect the efficiency of the device in filtering different fluids. 7. Filter Disc Installation Process
عرض المزيدPressure filtration, Part II--Continuous filtration 399 12.3.2.4 Krupp pressure disc filter A recent arrival in amongst the continuous pressure filters is the Krupp filter 28. ... the intake of the compressor is connected to the filtrate side of the filter and the gas goes round in a closed circuit. The method used to discharge the cake ...
عرض المزيدClosed Circuit Reverse Osmosis (CCRO) represents one of the most fundamental breakthroughs in reverse osmosis since its commercialization in the 1960's. The simple …
عرض المزيدIf you were just calculating pressure loss from pipe flow, you would expect it to be insignificant. Short, smooth pipe of an appropriate diameter. The reality is that, at each of the flow rates tested in the original straight pipe sample, this one has about double the head loss, maxing out at nearly 6 inches of pressure drop at 0.9 gpm.
عرض المزيدThe Hydrotech Discfilter is a patented design that uses discs with filter media to remove solids and produce high quality effluent. It is ideal for effluent polishing, phosphorus …
عرض المزيدPreviously, only sand filters could fulfill such a task, as no filter media with the required characteristics for mechanical filtration existed. Now, disc filters in continuous operation – and with integrated backwashing – are purifying huge quantities of wastewater, and offering conventional sand filters some serious competition.
عرض المزيدGate valves are used to shut off the flow of fluid by inserting a rectangular gate or wedge into the path of a flowing fluid. Gate valves require very little space along the pipe axis and hardly restrict the flow of fluid when the gate is fully opened enabling gate valves to offer straightway flow with very little pressure drop.
عرض المزيدActivated by a predefined command (differential pressure or time), alternate units of the disc filter system go into backflush mode. The inlet valve is shut as the drain is automatically opened. During the backflush process, the compression spring is released and the pressure difference is eliminated. The spine piston rises up, releasing the …
عرض المزيدwoven media filter for fine solids removal and product recovery. This technology offers a large filter area in a small footprint, making it well suited for various industrial …
عرض المزيدHigh – requires a high pressure to operate correctly 24hrs/day. ... The result is a technology that removes particles down to submicron levels at 4 to 5 times the hydraulic flow rate of traditional media filters, while requiring up to 50% less water for backwash. ... During the cooling process, the cooling water absorbs large volumes of ...
عرض المزيدon the two sides of the disc segments. • As the solids accumulate on the inside of the filter media, the flow of water through the disc is impeded. The water level inside of the discs begins to rise and a level sensor is triggered to start the drum rotation and backwash cycle. • A high pressure rinse removes the accumulated solids from the ...
عرض المزيدAt set pressure however the flow is still acting on the enlarged disc area, which will keep the valve open. A further reduction in pressure is required until the spring force F s is again greater than F p and the safety valve begins to close. At the so called reseating pressure the disc will touch the nozzle again and the safety valve closes.
عرض المزيدWherever difficult to filter products or large amounts of suspension are to be filtered – such as concentrates from ore, coal and mineral processing or their tailings – BoHiBar Disc filters offer outstanding solutions.. BoHiBar Disc filters represent the most advanced technology for continuous pressure filtration.High filtration pressure differences up to …
عرض المزيدDisc filters are a type of water filter, initially intended for irrigation water, sediments of well, hole House and Industrial use. ... or when the pressure drop in the filtration system reaches a certain level. In the backwash process, the flow is directed in the opposite direction to that of filtration, and the discs decompress. In this way ...
عرض المزيدdiaphragm valve at bottom side of disc filter arrangement, diaphragm valve closes the flow direction from outside to inside of filter discs. Now, the back wash flow from the outlet comes to inner surface of filter disc arrangement. This flow creates pressure on rubber spring, so that it tightens the spring in top direction and filter
عرض المزيد• New Automat Automatic Disc Filter "AQUA DISC" offers high cleaning ef˜ciency with non stop irrigation while ˚ushing ... During the ˚ushing process, a minimum back pressure of 2 bar (30 PSI) should be maintained at the outlet of the ... • Gradually open the inlet & outlet valves fully & allow water to flow from the filter .
عرض المزيدCooling duty is always a lost duty; therefore cooling water should be used only when the heat cannot be recovered by other means. The cooling water system is considered to be a critical utility system; local or total loss of cooling water is a primary cause of process plant upset with failure of machinery equipment, column pressurization; leads to, PSVs …
عرض المزيدThis increased accuracy can be used to deliver commercial benefits in addition to the obvious performance benefits. For example, it is not untypical for a plant to have one or two spare bursting discs in stores, waiting for an over-pressure event or a planned maintenance interval, at which point the in-service disc is removed and one of …
عرض المزيدNormally in thermal power plants, forced draught is used at the entry of air from the atmosphere, and induced draught is used at the exit of flue gases from the system through the chimney.. Water Steam Circuit. The water-steam circuit of a thermal power generating plant is a semi-closed circuit. Here comparatively not much water is …
عرض المزيدRecently, several RO-based batch and semi-batch technologies have been successfully demonstrated for high recovery operation in industrial wastewater and municipal water reuse applications. These include flow reversal (FR)-RO, pulse flow RO (PFRO), and closed-circuit reverse osmosis (CCRO) [13], [14], [15], [16].
عرض المزيدA disc filter (DF) is an important component in a micro irrigation system. However, it has a high head loss and low filtration efficiency, which can lead to the inoperability of micro irrigation systems. To improve the filtration ability and to decrease the pressure loss of the irrigation system, it is necessary to internalize the hydraulic …
عرض المزيدAdding pebble crushing as a unit operation is the most common variant to closed-circuit AG/SAG milling (instead of direct recycle of oversize material ). The efficiency benefits (both in terms of grinding efficiency and in capital efficiency through incremental throughput) are well recognized. ... D. Milling Circuit Flow Sheet. Types of ...
عرض المزيدThe manual cleaning process should be completed at least once a year. Reapply silicone grease to all O-rings. Test the back-flush (if an automatic filter). Additional maintenance for automatic disc filters During the season. For automatic disc filters – test the back-flush. • The back-flush should occur at maximum 0.5 bar (7 psi) pressure ...
عرض المزيدFilson Sintered Metal Filter Disc Pore Sizes: 40-100 µm: preparative work and coarse filtration. 16-40 µm: analytical work with medium precipitates. 10-16 µm: fine precipitates filtration. 1-1.6 µm: ultra-fine filtration of biological solutions. Filson Sintered Metal Filter Disc Features: Withstand the temperature range of -200℃-600℃
عرض المزيدCIP and Sanitation of Process Plant Design for cleanability The design of the process plant must conform to all documented hygienic design criteria. It is not usually possible to apply a CIP system to a process plant that was not designed for CIP in the first place. Such hygienic design criteria have been extensively documented
عرض المزيد